Eight Port RS-232/422/485 DB-9 to TCPIP Netcom Advanced
Serial Device
|
 |
 |
|
VS NetCom 813 is
an industrial-strength network-based serial device server for connecting
four RS232/422/485 devices like CNC, PLC, weighting scale, scanner and other
devices directly to the 10/100Mbps Ethernet network running TCP/IP. In
addition to allowing serial devices to get networked, any host (PC Server or
Workstation) without network access can also access remote serial device via
adding NetCom devices to the existing serial port. NetCom 813 can be
configured over Driver Panels, WEB Browser, serial Port, Telnet, SNMP and
serves as a transparent serial channel without platform and distance
limitation.
Applications:
Industrial / Factory / Laboratory automation, SCADA system, Automatic
warehouse control system, Building automation system, Wafer fabrication
system, Self-service banking system, Retail system, Other remote and
distributed serial devices control
|
|
Features |
 |
Controls 8 RS232/422/485 devices located virtually
anywhere via Ethernet or Internet
|
 |
Secure encryption on Ethernet
|
 |
LAN interface 10BaseT/100BaseTx Ethernet
|
 |
Driver automatically finds NetCom devices in the
network
|
 |
Configuration over Driver Panels, serial Port,
Telnet, WEB Browser, SNMP
|
 |
Automatic mode switching between Driver and Raw
Mode
|
 |
Supports TCP/IP, UDP, Telnet, DHCP, ICMP, HTTP,
SNMP V1/2c/3, DNS, PPP, openVPN
|
|
Back to Top |
|
Specifications |
|
Hardware
 |
Processor: ARM
9 166 MHz |
 |
I/O
controller: 16C950 or compatible |
 |
Memory: 16MB
SDRAM, 2 MB Flash |
 |
Connector
type: DB-9 male for serial Port, RJ45 for Ethernet |
|
|
Interface
 |
Ethernet
interface: Auto-detecting 10BaseT/100BaseTx |
 |
Protocols:
TCP/IP, UDP, Telnet, PPP, DHCP, ICMP, HTTP, LPD, SNMP V1/2c/3, DNS |
 |
Serial
interface: RS232/422/485 |
 |
No. of port: 8 |
 |
Available
Modes: RS232 full duplex; RS422 full duplex, RS485 4 wire full duplex,
RS485 2 wire half duplex with echo; RS485 2 wire half duplex without
echo |
 |
Signals:
RS-232 TxD,RxD, RTS,CTS, DTR,DSR, DCD, RI, GND; RS422: Tx+/-, Rx+/-, GND;
RS485 2 wire Data+/-, GND; RS485 4 wire Tx+/-, Rx+/-, GND |
 |
RS485 Data
control: Controlled by ART (Automatic Receive Transmit control) or RTS |
|
|
Performance
 |
Speed: up to
460 kbps |
 |
Parity: None,
even, odd, space, mark |
 |
Data bits: 5,
6, 7, 8 |
 |
Stop bits: 1,
1.5, 2 |
 |
IRQ: None |
 |
I/O address:
None |
|
|
Operating Modes
 |
Driver mode:
VScom Driver for Windows NT 4.0, 2000, XP and 2003, Vista.
Driver Mode creates virtual Com port. |
 |
TCP Raw
Server: Raw data transfer over TCP/IP. Accepts multiple incoming
connections. |
 |
TCP Raw
Client: Raw data transfer over TCP/IP. Connects to multiple hosts or
devices waiting for incoming connections. |
 |
TCP Advanced
Settings: Special settings for user-defined modes |
 |
UDP Mode: Raw
data transfer by UDP. The NetCom is client and server at the same time.
Timeout functionality, maximum packet size and a configurable trigger
string define the packets of incoming data to send over UDP |
 |
Null Modem
Tunnel: Connecting two NetCom used as virtual null modem cable. |
 |
IP Modem: The
serial port emulates a standard modem. Operates by AT-commands, and
dials to IP-Addresses instead of phone numbers.
Windows "INF"-Driver provided for installation. |
 |
Print Server:
The NetCom accepts print jobs, and spools them to the attached serial
printer. Operates as of RFC1197, similar to the line printer daemon in
Unix-systems |
 |
PPP net: A
Modem attached to a serial port provides Dial-In/-Out. This allows
access to the serial ports without a dedicated Ethernet connection. |
|
|
Power & Enviorment
 |
Power supply
Adapter included: 12V DC, 1A. Connected by Terminal block |
 |
Dimension:
171× 94×46 mm³ (W×L×H), 193×99×47 mm³ with DB9 connectors and ears |
 |
Operating
Temp: 0°C - 55°C |
 |
Storage Temp:
−20°C – 85°C |
 |
Case: metal |
 |
Weight: 0.9kg |
|
|
Special Features
 |
Installation:
Configuration utility automatically finds NetCom devices in the network |
 |
Operating
mode: Automatic mode switching between Driver and TCP RAW mode.
With TCP Advanced settings it is possible to configure the NetCom for
using it in multiple modes, so it decides automatically which mode
should be used. |
 |
PPP Access:
Dial-In to a modem attached to a serial port using Point to Point
Protocol. TCP/IP is transported over the serial line, allowing access to
configuration and the serial ports, even without Ethernet. A Dial-Out
option is also provided. |
 |
Configuration:
Configuration over Driver Panels, NetCom Manager, WEB Browser, serial
console, Telnet, SNMP |
 |
SNMP: special
VScom MIB included |
 |
DNS: Domain
Name Server support |
 |
Firewall:
Special precautions for Firewall environments |
 |
Firmware:
Firmware update over WEB Browser, Telnet, ComPort |
 |
LED's: LED's
for Power, serial Tx, Rx, Ethernet Link, Speed |
|
|
Security
 |
Password
access: Every capabilities of configuration use the same password
including SNMP V3 |
 |
Secure
communication: OpenVPN™ tunnel provides security on Ethernet. The tunnel
protects the configuration as well as all serial data. It is also usable
across the Internet. Strong encryption by AES up to 256 bit keys. |
|
|
Package include:
 |
NetCom 813, Power supply adapter 12V, 1000mA, CD-ROM with Driver and
configuration software, Printed Quick Installation Guide |
 |
Optional Accessories:
DK-35A DIN-Rail mounting kit |
|
Back to Top |
|
| Israel, IL, ישראל |
vs-com vscom |
שרת
מוגן
TCP/IP
עם 8 יציאות של
422/485/RS-232